4core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable

Model NO.: XLPE power cable
Wire Core Material: Tinned Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: Yjv32
Brand: Jinshui
Trademark: Jinshui
Transport Package: Wooden Drums
Specification: 2.2*1.1*1.0*1.1
Origin: China
HS Code: 8544492100
Model NO.: XLPE power cable
Wire Core Material: Tinned Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: Yjv32
Brand: Jinshui
Trademark: Jinshui
Transport Package: Wooden Drums
Specification: 2.2*1.1*1.0*1.1
Origin: China
HS Code: 8544492100

3 Core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable

Product Description

 

1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards as request.

 

2. Rated Voltage of XLPE Cable:

0.6/1KV 6/10KV;8.7/15KV;12/20KV;18/20KV;21/35KV;6/35KV

 

3. Construction of XLPE Cable:

Conductor:Copper or Aluminum

Insulation:XLPE

Inner sheath:PVC or PE

Armoured:Galvanized steel tape,Galvanized steel wire

Outer Sheath:PVC or PE

NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.

Also can do according to the customer's request.

 

4. Characters of XLPE Cable:

a.Max  Long-time operating temperature of XLPE insulated cable is 90°C

b.Installing temperature of cable should not be less than 0°C

c.Max short-circuit temperature is not exceed 250°C,Not more than5 Sec.

d.Unable be laid without the limit of fall with enough mechanical pull,Single core cable can not be laid in iron tube or fixed by circled iron tools around cables

 

5. Description & Application of XLPE Cable:

 

TYPE

NAME

Main Application

CU core

AL core

 

 

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.Unable to bear external mechanical forces,but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.Able to bear external mechanical forces,but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,PVC/PE sheathed power cable

For laying in water and seabed.Able to bear positive pressure and pulling force


4core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable

4core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable



4core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable



 

3 Core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable

Product Description

 

1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards as request.

 

2. Rated Voltage of XLPE Cable:

0.6/1KV 6/10KV;8.7/15KV;12/20KV;18/20KV;21/35KV;6/35KV

 

3. Construction of XLPE Cable:

Conductor:Copper or Aluminum

Insulation:XLPE

Inner sheath:PVC or PE

Armoured:Galvanized steel tape,Galvanized steel wire

Outer Sheath:PVC or PE

NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.

Also can do according to the customer's request.

 

4. Characters of XLPE Cable:

a.Max  Long-time operating temperature of XLPE insulated cable is 90°C

b.Installing temperature of cable should not be less than 0°C

c.Max short-circuit temperature is not exceed 250°C,Not more than5 Sec.

d.Unable be laid without the limit of fall with enough mechanical pull,Single core cable can not be laid in iron tube or fixed by circled iron tools around cables

 

5. Description & Application of XLPE Cable:

 

TYPE

NAME

Main Application

CU core

AL core

 

 

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.Unable to bear external mechanical forces,but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.Able to bear external mechanical forces,but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,PVC/PE sheathed power cable

For laying in water and seabed.Able to bear positive pressure and pulling force


4core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable

4core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable



4core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable



 

Wire Harness

Spare Part slot machine

Guangzhou Ruihong Electronic Technology CO.,Ltd , https://www.callegame.com

Posted on