The default value after the threshold is initialized is "8"
The current light quantity value is "0" when there is no workpiece
When there is a workpiece, the current light intensity value is "174"
When there is no object to be measured, switch to SET mode, press the UP/DOWN button for 1s, and "----" flashes
Press the UP/DOWN button again for 3 seconds to switch back to RUN mode, the threshold value is automatically set to +6% of the current light value
Set to L-ON, at this time, when the detected object has output, the action light is on
When there is no object to be measured, switch to SET mode, press the UP/DOWN button for 1s, and "----" flashes
Switch back to RUN mode, the threshold is automatically set to -6% of the current light value
Set to D-ON, at this time, when the detected object has output, the action light is on
Three, two-point teachingWhen there is an object under test, switch to SET mode, press UP/DOW for 1s, and "----" flashes.
When there is no object to be measured, press the UP/DOWN button for 1s, and the set value flashes twice.
Switch back to the RUN mode, and the threshold value is automatically set to the middle value of the current brightness value in the case of workpieces and the case of no workpieces.
Set to L-ON, at this time, when the detected object has output, the action light is on.