High-low temperature wet heat alternating test box operation

High-low temperature wet heat alternating test box operation
First, the use of high and low temperature heat and humidity test box:
1. Place the test sample on the sample holder in the test chamber.
2. Turn on the power "ON" on the panel.
(1) If the test temperature is 50° and humidity 95% for 5 hours, click on the “Table of Contents” and “Operation Settings” in the upper left corner of the instrument and then “Set Value” after the “Run Mode”, then click on the “Contents” point in the upper left corner. set up". The date adjustment is followed by (start time) year, month, day, hour, and minute. The number in the box, there are many numbers below, and you need to click on it. Then click "ENT (confirmation button)" to set the completion of the return; if not, click "ESC (return key)" for the appointment time to the end of the test. After setting, click on the reservation to set the next "ON". The last point is the "Table of Contents" point in the upper left corner of the "monitoring screen", "Directory", "Setpoint stop", "Switch (Screen)" appears, and two rows of numbers appear in the box under temperature. Point 40 and ENT, then there are 2 rows of numbers, 95 and ENT. Click "Run" in the lower right corner. The equipment can start the above test requirements.
(2) If the test temperature is first: 40 degrees for 5 hours, and then the test temperature is 60 degrees for 3 hours, then there are 3 cycles:
The first step: Click the “Directory” “Operation Settings” in the upper left corner of the instrument, and then click “Program” after “Run Mode” and then click “Program” in the upper left corner. “Program Settings” “Program Edit”, the program number will appear (with memory function). Segment number temperature and humidity time TS1 TS2 TS3 TS4. There are 01-04 at the segment number.
The second step, the third step, the fourth step, the fifth step, and the sixth step are omitted. Refer to the above steps and icons
Second, the use of high and low temperature heat and humidity test box Note:
1, can not open the door in the premise of the test (careful burn).
2, can not allow non-testers to operate the machine.
3, can not work in the case of alarm sound equipment.
4. Do not start the compressor frequently (reduce the life of the compressor).
5, pay attention to the water tank is indispensable, this will burn the heating tube.
6, can not change the internal parameters of the instrument.
Note: Wuhan ShangMei Test Equipment Co., Ltd. provides a variety of equipment control panels for reference only

Posted on