Vs1 Vacuum Circuit Breaker Indoor Type for Switchgear

  • Model NO.: VS1
  • Operation: Electric Type
  • Arc-extinguishing Medium: Vacuum
  • Structure: Conventional Circuit Breaker
  • Certification: ISO9001-2000, CE, CCC
  • Transport Package: CTN
  • HS Code: 85352100
  • Breaking Capacity: High Voltage Circuit Breakers
  • Speed: High-Speed Circuit Breaker
  • Installation: Insert
  • Type: Circuit Breaker
  • Trademark: CNC
  • Origin: Zhe Jiang, China
Vs1 Vacuum Circuit Breaker Indoor Type for Switchgear

1. Rated voltage: 12KV
2. 50Hz
3. -25degree-+40degree
4. CE, GB, IEC, ISO9001, 14001
5. OEM, ODM
 

Main application
VCP-12 type indoor high voltage vacuum circuit breaker is the indoor switch device for three-phase AC 50Hz, rated voltage 12kA power system, can be used for electrical equipment control and protection in power plant, substation and industrial and mining enterprises, and is suitable for frequent operation place, can be installed in the KYN28-12 type and other armored cabinet, can also be installed on the fixed cabinet or gas insulated cabinet.

 

Design feature
VCP-12kV indoor medium voltage sealed vacuum circuit breaker

(12kV, .4000A, .50kA)
VCP indoor medium voltage sealed vacuum circuit breaker with maintenance free sealed vacuum pole, can equipped with modular spring assembling actuator and permanent magnetic actuator; has the features of reliable performance, long mechanical life, maintenance free, small mechanical movement, has the advantages of simple structure, good process performance, but also can be applied to all kinds of bad working environment.
VCP circuit breaker pole adapts the solid insulation sealing technology, seal the vacuum interrupter and primary main galvanic circle and other parts into strong insulation, high mechanical strength pole with epoxy resin, avoid the influence of adverse operating environment on the primary circuit external insulation, realizes completely maintenance free.
VCP circuit breaker adapt ultra low resistance type vacuum interrupter, meet the VCP circuit breaker requirements on the temperature rise at big current operation situation and reduces the power losses.
VCP circuit breaker adapt optimization and modular spring operating mechanism, simple structure, stable performance, convenient maintenance; modular production process is good, easy standardization production, short delivery cycle.

 

Main technical parameters

Vs1 Vacuum Circuit Breaker Indoor Type for Switchgear




 

Serial No. Item Unit Parameters
01 Rated voltage kV 12
02 Rated short-term frequency withstand voltage kV 42
03 Rated lightning impulse withstand voltage kV 75
04 Rated frequency Hz 50
05 Rated current A 630
 
630
1250
1250 1600
06 Rated short-circuit break current kA 20 25 31.5
07 Rated short-term withstand current kA 20 25 31.5
08 Rated short-circuit break and close current kA 50 63 80
09 Rated short-circuit current lasting time s 4
10 Rated short-circuit break and close time t 50
 
11 Rated operation order   O-0.3s-CO-180s-CO 
12 Close time ms ≤ 70
13 Break time ms ≤ 50
14 Rated storage operation voltage V 220/110
15 Storage time s ≤ 10
16 Mechanical life t ≥ 10000

LED Tube

T5 Tube Light,Led Fluorescent Tube,Led Fluorescent Light

enghua Jade Motor Co., Ltd. , http://www.nsledbulb.com

Posted on