Beauty Salons Air Conditoning Monoblock Water Source Geothermal Heat Pump

Model NO.: ESSW20GCH
Certification: CE, CCC, SGS
Working Mode: Cooling&Heating&Hot Water
Structure: Monoblock Type
Compressor: Copeland Scroll
Expansion Valve: Thermal Type
Trademark: Eurostars
Transport Package: Standard Export Package
Specification: CE Approval
Origin: Guangdong, Prc.
HS Code: 8418692090
Beauty Salons Air Conditoning Monoblock Water Source Geothermal Heat Pump

1. Unit features-Eurostars water cooled geothermal source water chiller heat pump
(1)High efficiency and energy saving;
(2) Low noise and reliability operation;
(3)Intellectualized control system;
(4)Easy simply installtion and maintenance; 
 
Eurostars geothermal source heat pump is one of the most competitive products, consists of famous brand compressor, electric controlling components, high efficient heat exchanger, etc. With compact structure, elegant appearance, sufficient cooling and heating capacity, high efficiency and maintenance easily. 
  
Eurostars geothermal souce heat pump takes soil underground as heat source, and it is special designed with several working models: heating, cooling, hot water, heating + hot water, cooling +hot water,which is widely used for hotel, villa, hospital, school, etc.

2. Nomenclature-Eurostars water cooled geothermal source water chiller heat pump
ES  S     W      25       G     C     Q    
1    2      3       4         5      6     7   
(1) : ES Eurostars
(2) :S Compressor type: S-Scroll type
(3) :W Product series: W-Water cooled series
(4):25 Product seris NO:(USRT/KW/HP)
(5):G G-Geothermal    Omitted:water source                              
(6):C Frame type: C-Cabinet type
(7): Q Function: H-Heat pump  Q-Heat pump with recovery  Cooling or heating only: omitted

3.Technical parameter-Eurostars water cooled geothermal source water chiller heat pump
Please ask salesman for detailed complete data or visit our website:
www.eurostarschina.com  
Geothermal Source Heat Pump (Heating-Cooling)
Model ESSW10GCH ESSW15GCH ESSW20GCH ESSW25GCH ESSW40GCH
Technical Parameter
Heating input power  Heating mode KW 2.1 2.35 4.15 4.9 8.35
Heating capacity KW 10.5 11.8 21.3 25.2 42.6
COP   5.00  5.02  5.13  5.14  5.10 
Cooling input power Cooling mode KW 1.5 1.7 3 3.4 6
Cooling capacity KW 6.8 7.8 14 16.5 28
EER   4.53  4.59  4.67  4.85  4.67 
Pipe size mm 25 25 25 25 32
Unit noise db 50 50 50 50 50
N.W. kg 90 90 123 133 286
G.W. kg 94 94 133 143 301
Level of protection   IPX4 IPX4 IPX4 IPX4 IPX4
Electric shock proof grade   I I I I I
Unit Standard Components
Unit cabinet   Galvanized sheet/ Spray coating / gray color
Unit dimension mm 710*520*1000 710*520*1000 710*520*1000 710*520*1000 1280*830*800
Packing dimension mm 760*570*1130 760*570*1130 760*570*1130 760*570*1130 1330*880*930
Refrigerant   R407C/2.4kg*1 R407C/2.4kg*1 R407C/3.3kg*1 R407C/3.6kg*1 R407C/3.3kg*2
Power supply   220V~240V/50Hz 380V~415V/50Hz/3ph
Unit compressor   Copeland.
load side heat exchanger   Double-pipe 
Source side heat exchanger   Plate Type
4-way valve   SANHUA
Thermal expansion valve   Emerson
AC contactor and thermal relay   Fuji
Controller   Eurostars multiple function controller
Protection function   Temperature protection, time protection, water flow protection, antifreeze protection, current protection
Water pressure switch   0.015Mpa :OFF,  0.03Mpa: ON
High pressure switch   3.0/3.4MPa 
Low pressure switch   0.15/0.32MPa
Working mode   Heating mode and cooling mode
Geothermal Source Heat Pump (Heating-Cooling)
Model ESSW50GCH ESSW55GCH ESSW75GCH ESSW95GCH  
Technical Parameter
Heating input power  Heating mode KW 9.84 10.8 14.5 19.5  
Heating capacity KW 50.4 56.7 74.8 99.4  
COP   5.12  5.25  5.16  5.10   
Cooling input power Cooling mode KW 6.8 7.7 9.9 13.2  
Cooling capacity KW 33 37.1 49.4 67  
EER   4.85  4.82  4.99  5.08   
Pipe size mm 32 32 50 65  
Unit noise db 55 55 55 55  
N.W. kg 306 358 552 592  
G.W. kg 321 378 582 632  
Level of protection   IPX4 IPX4 IPX4 IPX4  
Electric shock proof grade   I I I I  
Unit Standard Components
Unit cabinet   Galvanized sheet/ Spray coating / gray color
Unit dimension mm 1280*830*800 1320*840*1130 1750*1120*1160 2000*1120*1160  
Packing dimension mm 1330*880*930 1410*940*1290 1850*1225*1340 2100*1225*1340  
Refrigerant   R407C/3.6kg*2 R407C/5kg*2 R407C/7kg*2 R407C/9kg*2  
Power supply   380V~415V/50Hz/3ph
Unit compressor   Copeland 1pc  
load side heat exchanger   Double-pipe  Shell and tube   
Source side heat exchanger   Plate Type
4-way valve   SANHUA
Thermal expansion valve   Emerson
AC contactor and thermal relay   Fuji
Controller   Eurostars multiple function controller
Protection function   Temperature protection, time protection, water flow protection, antifreeze protection, current protection
Water pressure switch   0.015Mpa :OFF,  0.03Mpa: ON
High pressure switch   3.0/3.4MPa 
Low pressure switch   0.15/0.32MPa
Working mode   Heating mode and cooling mode
Notes:
(1)Cooling: source side inlet/outlet water temp: 35ºC/30ºC, load side inlet/outlet water temp: 12ºC/7ºC;
(2)Heating: source side inlet/outlet water temp:15ºC/10ºC,load side inlet/outlet water temp:50ºC/55ºC;
(3)Working range:source side water inlet temp: 0ºC-40ºC

4.Quotation Remarks-Eurostars water cooled geothermal source water chiller heat pump
(1)Packing: Standard export package
(2)Delivery Day: 30 working days after deposit is confirmed
(3)Delivery term: CIF,FOB or CNF EX-Work are welcomed
(4)Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
(5)Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, 
we'll supply you the spare parts for free, and permanent technical support & consultation all life long 
for the machines.
(6)Validity: 20 days
(7)Payment currency: USD

Flat Wire Power Inductors

Flat Wire Power Inductors,Flat Copper Wire Inductors,Flat Coil High Current Inductors,Flat Wire High Power Inductors

Shenzhen Sichuangge Magneto-electric Co. , Ltd , https://www.scginductor.com

Posted on