Model NO.: ESSW20GCH
Certification: CE, CCC, SGS
Working Mode: Cooling&Heating&Hot Water
Structure: Monoblock Type
Compressor: Copeland Scroll
Expansion Valve: Thermal Type
Trademark: Eurostars
Transport Package: Standard Export Package
Specification: CE Approval
Origin: Guangdong, Prc.
HS Code: 8418692090
Beauty Salons Air Conditoning Monoblock Water Source Geothermal Heat Pump1. Unit features-Eurostars water cooled geothermal source water chiller heat pump
(1)High efficiency and energy saving;
(2) Low noise and reliability operation;
(3)Intellectualized control system;
(4)Easy simply installtion and maintenance;Â
Â
Eurostars geothermal source heat pump is one of the most competitive products, consists of famous brand compressor, electric controlling components, high efficient heat exchanger, etc. With compact structure, elegant appearance, sufficient cooling and heating capacity, high efficiency and maintenance easily.Â
 Â
Eurostars geothermal souce heat pump takes soil underground as heat source, and it is special designed with several working models: heating, cooling, hot water, heating + hot water, cooling +hot water,which is widely used for hotel, villa, hospital, school, etc.
2. Nomenclature-Eurostars water cooled geothermal source water chiller heat pump
ES Â S Â Â W Â Â Â 25 Â Â Â G Â Â C Â Â Q Â Â
1Â Â Â 2 Â Â Â 3 Â Â Â 4Â Â Â Â Â Â Â Â 5Â Â Â Â Â 6 Â Â 7 Â Â
(1) : ES Eurostars
(2) :S Compressor type: S-Scroll type
(3) :W Product series: W-Water cooled series
(4):25Â Product seris NO:(USRT/KW/HP)
(5):G G-Geothermal   Omitted:water source               Â
(6):C Frame type: C-Cabinet type
(7): Q Function: H-Heat pump  Q-Heat pump with recovery  Cooling or heating only: omitted
3.Technical parameter-Eurostars water cooled geothermal source water chiller heat pump
Please ask salesman for detailed complete data or visit our website:
www.eurostarschina.com Â
Geothermal Source Heat Pump (Heating-Cooling) | |||||||
Model | ESSW10GCH | ESSW15GCH | ESSW20GCH | ESSW25GCH | ESSW40GCH | ||
Technical Parameter | |||||||
Heating input power | Heating mode | KW | 2.1 | 2.35 | 4.15 | 4.9 | 8.35 |
Heating capacity | KW | 10.5 | 11.8 | 21.3 | 25.2 | 42.6 | |
COP | Â | 5.00Â | 5.02Â | 5.13Â | 5.14Â | 5.10Â | |
Cooling input power | Cooling mode | KW | 1.5 | 1.7 | 3 | 3.4 | 6 |
Cooling capacity | KW | 6.8 | 7.8 | 14 | 16.5 | 28 | |
EER | Â | 4.53Â | 4.59Â | 4.67Â | 4.85Â | 4.67Â | |
Pipe size | mm | 25 | 25 | 25 | 25 | 32 | |
Unit noise | db | 50 | 50 | 50 | 50 | 50 | |
N.W. | kg | 90 | 90 | 123 | 133 | 286 | |
G.W. | kg | 94 | 94 | 133 | 143 | 301 | |
Level of protection |  | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
Electric shock proof grade |  | I | I | I | I | I | |
Unit Standard Components | |||||||
Unit cabinet |  | Galvanized sheet/ Spray coating / gray color | |||||
Unit dimension | mm | 710*520*1000 | 710*520*1000 | 710*520*1000 | 710*520*1000 | 1280*830*800 | |
Packing dimension | mm | 760*570*1130 | 760*570*1130 | 760*570*1130 | 760*570*1130 | 1330*880*930 | |
Refrigerant | Â | R407C/2.4kg*1 | R407C/2.4kg*1 | R407C/3.3kg*1 | R407C/3.6kg*1 | R407C/3.3kg*2 | |
Power supply |  | 220V~240V/50Hz | 380V~415V/50Hz/3ph | ||||
Unit compressor |  | Copeland. | |||||
load side heat exchanger |  | Double-pipe | |||||
Source side heat exchanger |  | Plate Type | |||||
4-way valve |  | SANHUA | |||||
Thermal expansion valve |  | Emerson | |||||
AC contactor and thermal relay |  | Fuji | |||||
Controller |  | Eurostars multiple function controller | |||||
Protection function |  | Temperature protection, time protection, water flow protection, antifreeze protection, current protection | |||||
Water pressure switch |  | 0.015Mpa :OFF,  0.03Mpa: ON | |||||
High pressure switch |  | 3.0/3.4MPa | |||||
Low pressure switch |  | 0.15/0.32MPa | |||||
Working mode |  | Heating mode and cooling mode |
Geothermal Source Heat Pump (Heating-Cooling) | |||||||
Model | ESSW50GCH | ESSW55GCH | ESSW75GCH | ESSW95GCH | Â | ||
Technical Parameter | |||||||
Heating input power | Heating mode | KW | 9.84 | 10.8 | 14.5 | 19.5 |  |
Heating capacity | KW | 50.4 | 56.7 | 74.8 | 99.4 |  | |
COP | Â | 5.12Â | 5.25Â | 5.16Â | 5.10Â | Â | |
Cooling input power | Cooling mode | KW | 6.8 | 7.7 | 9.9 | 13.2 |  |
Cooling capacity | KW | 33 | 37.1 | 49.4 | 67 |  | |
EER | Â | 4.85Â | 4.82Â | 4.99Â | 5.08Â | Â | |
Pipe size | mm | 32 | 32 | 50 | 65 |  | |
Unit noise | db | 55 | 55 | 55 | 55 |  | |
N.W. | kg | 306 | 358 | 552 | 592 | Â | |
G.W. | kg | 321 | 378 | 582 | 632 | Â | |
Level of protection |  | IPX4 | IPX4 | IPX4 | IPX4 |  | |
Electric shock proof grade |  | I | I | I | I |  | |
Unit Standard Components | |||||||
Unit cabinet |  | Galvanized sheet/ Spray coating / gray color | |||||
Unit dimension | mm | 1280*830*800 | 1320*840*1130 | 1750*1120*1160 | 2000*1120*1160 |  | |
Packing dimension | mm | 1330*880*930 | 1410*940*1290 | 1850*1225*1340 | 2100*1225*1340 |  | |
Refrigerant | Â | R407C/3.6kg*2 | R407C/5kg*2 | R407C/7kg*2 | R407C/9kg*2 | Â | |
Power supply |  | 380V~415V/50Hz/3ph | |||||
Unit compressor |  | Copeland 1pc |  | ||||
load side heat exchanger |  | Double-pipe | Shell and tube |  | |||
Source side heat exchanger |  | Plate Type | |||||
4-way valve |  | SANHUA | |||||
Thermal expansion valve |  | Emerson | |||||
AC contactor and thermal relay |  | Fuji | |||||
Controller |  | Eurostars multiple function controller | |||||
Protection function |  | Temperature protection, time protection, water flow protection, antifreeze protection, current protection | |||||
Water pressure switch |  | 0.015Mpa :OFF,  0.03Mpa: ON | |||||
High pressure switch |  | 3.0/3.4MPa | |||||
Low pressure switch |  | 0.15/0.32MPa | |||||
Working mode |  | Heating mode and cooling mode |
(1)Cooling: source side inlet/outlet water temp: 35ºC/30ºC, load side inlet/outlet water temp: 12ºC/7ºC;
(2)Heating: source side inlet/outlet water temp:15ºC/10ºC,load side inlet/outlet water temp:50ºC/55ºC;
(3)Working range:source side water inlet temp: 0ºC-40ºC
4.Quotation Remarks-Eurostars water cooled geothermal source water chiller heat pump
(1)Packing: Standard export package
(2)Delivery Day: 30 working days after deposit is confirmed
(3)Delivery term: CIF,FOB or CNF EX-Work are welcomed
(4)Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
(5)Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period,Â
we'll supply you the spare parts for free, and permanent technical support & consultation all life longÂ
for the machines.
(6)Validity:Â 20Â days
(7)Payment currency: USD
Flat Wire Power Inductors,Flat Copper Wire Inductors,Flat Coil High Current Inductors,Flat Wire High Power Inductors
Shenzhen Sichuangge Magneto-electric Co. , Ltd , https://www.scginductor.com